enviro tech industrial product

Aerosense Mack Magnehelic Gauge SINGAPORE - Enviro Tech Industrial Produccts Delhi India

AEROSENSE DP Gauge

AEROSENSE DP Gauge - Analog


AEROSENSE DP Gauges are extensively used for measuring the differential pressure in pharma clean rooms, HVAC applications, pharmaceutical machinery,Pass Box,etc.


Other Information

  • Pay Mode Terms: T/T (Bank Transfer)
Aerosense Differential Pressure Indicator

Aerosense Differential Pressure Indicator is demanded for its impeccable qualities and features. It is extensively demanded in the applications areas where HVAC systems are installed to resolve the problem of humidity & temperature control. It is suitable for energy optimization and therefore widely used for the measurement of HVAC duct pressure. Along with the pr??cised operations it has integrated high speed differential pressure sensor that provide accurate results in a significant manner. 

Features: 

Integrated red LED seven segment display
Differential pressure sensor
Stainless steel at the back


Other Information

  • Pay Mode Terms: T/T (Bank Transfer)
Aerosense Differential Pressure Switch

The series of pressure switches Aerosense Differential Pressure Switch is the most updated one.Generally, they are applied in the fan, blower and filter monitoring as well as to measure the pressure and flow of gases & liquids in different industries. Enabled with the effective mechanism these switches have high-tech features & specifications such as selectable switching point adjustment and measurement unit facility in PA.Several additional accessories are also provided for the ease of users that primarily include metallic duct connectors,plastic dust connectors, and fixing screws. 


Features:

Pressure and flow monitoring
Two fixing screws
Metallic duct connectors
 

 

Aerosense Differential Pressure Gauge

Backed by years of experience of this domain, we present clients with the premium quality of Aerosense Differential Pressure Gage. Used for measurement of differential pressure, the pressure gauge is manufactured by using latest technology. In order to ensure high standards of quality, the Aerosense differential pressure gauge is procured from trusted vendors. 

 

Features:

  • Excellent measurement accuracy
  • Easy to use
  • Requires less maintenance

 


Other Information

  • Pay Mode Terms: T/T (Bank Transfer)
Aerosense Differential Pressure Cum Flow Transmitter

Aerosense Differential Pressure cum Flow Transmitter is technically engineered type of flow transmitter that is especially used in HVAC/R industry to control the flow, velocity and static of air pressure. Apart from measuring the flow of air control, this type of transmitter is used in the other major applications such as VAV domain and air flow monitoring across centrifugal fans & blowers. It supports low power consumption as well as enabled with the zero point calibration system. 

 
Features:

VAV applications
Minimum resistance
Piezo resistive


Other Information

  • Pay Mode Terms: T/T (Bank Transfer)
Differential Pressure Gauge

 Differential Pressure Gauge

CE approved Differential Pressure Gage with adjustable bookmarks feature indicates Positive, Negative or Differential pressure.

Applications:

  • Filter monitoring
  • Blower vacuum monitoring
  • Fan pressure indication
  • Duct, room or building pressures
  • Clean room positive pressure indication
Aerosense Differential Pressure Switch Model PS 200

 Aerosense Differential Pressure Switch Model PS 200

Series PS Differential Pressure Switch With dual scale field adjustable Set Point Knob

The Series PS Differential Pressure Switch is designed for pressure, vacuum and differential pressure. The dual scaled adjustment knob allows changes to the switching pressure to be made without a pressure gage. The PS is available in settings from 20 Pa to 4500 Pa. The compact size, adjustment knob and low cost make the PS the perfect choice for HVAC applications.

Product Applications:

Fan, Blower and filter monitoring
Pressure and Flow monitoring
Valve and damper monitoring

Service: Air & non aggressive gases
Material: ABS
Electrical Connection: 3 Screw terminal
Cable Entry: M16
Pressure Connection: Male 0 5 MM
Weight: 150 gms
Operation Temperature: -20 to 60° C
Storage Temperature: -40 to 85° C
Maximum Pressure: 50 kPA
IP Protection: IP54

2 Fixing Screws
2 Plastic duct connectors
2 m tube 0 4/7 mm
Metallic duct connectors

  • INTRODUCTIONS
  • TECHNICAL DATA
  • OPTIONAL ACCESSORIES
  • MODEL SUMMARY

Model Code

Pressure

range

Switching

difference

Accuracy of

Switching

point

Low limit typ.

Electrical

rating

resistive load

Accuracy of

Switching

Point

High limit typ.

Electrical

ratind

inductive load

PS200

20. .200 pa

10 pa

20 Pa±5 Pa

200 Pa±20Pa

01A/250VAC

Aerosense Differential Pressure Switch Model PS 300

 Aerosense Differential Pressure Switch Model PS 300

Series PS Differential Pressure Switch With dual scale field adjustable Set Point Knob

The Series PS Differential Pressure Switch is designed for pressure, vacuum and differential pressure. The dual scaled adjustment knob allows changes to the switching pressure to be made without a pressure gage. The PS is available in settings from 20 Pa to 4500 Pa. The compact size, adjustment knob and low cost make the PS the perfect choice for HVAC applications.

Product Applications:

Fan, Blower and filter monitoring
Pressure and Flow monitoring
Valve and damper monitoring

Service: Air & non aggressive gases
Material: ABS
Electrical Connection: 3 Screw terminal
Cable Entry: M16
Pressure Connection: Male 0 5 MM
Weight: 150 gms
Operation Temperature: -20 to 60° C
Storage Temperature: -40 to 85° C
Maximum Pressure: 50 kPA
IP Protection: IP54

2 Fixing Screws
2 Plastic duct connectors
2 m tube 0 4/7 mm
Metallic duct connectors

  • INTRODUCTIONS
  • TECHNICAL DATA
  • OPTIONAL ACCESSORIES
  • MODEL SUMMARY

Model Code

Pressure

range

Switching

difference

Accuracy of

Switching

point

Low limit typ.

Electrical

rating

resistive load

Accuracy of

Switching

Point

High limit typ.

Electrical

ratind

inductive load

PS300

30. .300 pa

20 pa

30 Pa±5 Pa

300 Pa±30Pa

03A/250VAC

2A/250VAC
Aerosense Differential Pressure Switch Model PS 500

 Aerosense Differential Pressure Switch Model PS 500

Series PS Differential Pressure Switch With Dual Scale Field Adjustable Set Point Knob

The Series PS Differential Pressure Switch is Designed For Pressure, Vacuum and Differential Pressure. The Dual Scaled Adjustment knob allows changes to the switching pressure to be made without a pressure gage. The PS is available in settings from 20 Pa to 4500 Pa. The compact size, adjustment knob and low cost make the PS the perfect choice for HVAC applications.

Product Applications:

Fan, Blower and filter monitoring
Pressure and Flow monitoring
Valve and damper monitoring

Service: Air & non aggressive gases
Material: ABS
Electrical Connection: 3 Screw terminal
Cable Entry: M16
Pressure Connection: Male 0 5 MM
Weight: 150 gms
Operation Temperature: -20 to 60° C
Storage Temperature: -40 to 85° C
Maximum Pressure: 50 kPA
IP Protection: IP54

2 Fixing Screws
2 Plastic duct connectors
2 m tube 0 4/7 mm
Metallic duct connectors

  • INTRODUCTIONS
  • TECHNICAL DATA
  • OPTIONAL ACCESSORIES
  • MODEL SUMMARY

Model Code

Pressure

range

Switching

difference

Accuracy of

Switching

point

Low limit typ.

Electrical

rating

resistive load

Accuracy of

Switching

Point

High limit typ.

Electrical

ratind

inductive load

PS500

30. .500 pa

20 pa

30 Pa±5 Pa

500 Pa±30Pa

03A/250VAC

2A/250VAC
Aerosense Differential Pressure Switch Model PS 600

 Aerosense Differential Pressure Switch Model PS 600

Series PS Differential Pressure Switch With Dual Scale Field Adjustable Set Point Knob

The Series PS Differential Pressure Switch is Designed For Pressure, Vacuum and Differential Pressure. The Dual Scaled Adjustment knob allows changes to the switching pressure to be made without a pressure gage. The PS is available in settings from 20 Pa to 4500 Pa. The compact size, adjustment knob and low cost make the PS the perfect choice for HVAC applications.

Product Applications:

Fan, Blower and filter monitoring
Pressure and Flow monitoring
Valve and damper monitoring

Service: Air & non aggressive gases
Material: ABS
Electrical Connection: 3 Screw terminal
Cable Entry: M16
Pressure Connection: Male 0 5 MM
Weight: 150 gms
Operation Temperature: -20 to 60° C
Storage Temperature: -40 to 85° C
Maximum Pressure: 50 kPA
IP Protection: IP54

2 Fixing Screws
2 Plastic duct connectors
2 m tube 0 4/7 mm
Metallic duct connectors

  • INTRODUCTIONS
  • TECHNICAL DATA
  • OPTIONAL ACCESSORIES
  • MODEL SUMMARY

Model Code

Pressure

range

Switching

difference

Accuracy of

Switching

point

Low limit typ.

Electrical

rating

resistive load

Accuracy of

Switching

Point

High limit typ.

Electrical

ratind

inductive load

PS600

40. .600 pa

30 pa

40 Pa±5 Pa

600 Pa±30Pa

03A/250VAC

2A/250VAC
Aerosense Differential Pressure Switch Model PS 1500

 Aerosense Differential Pressure Switch Model PS 1500

Series PS Differential Pressure Switch With Dual Scale Field Adjustable Set Point Knob

The Series PS Differential Pressure Switch is Designed For Pressure, Vacuum and Differential Pressure. The Dual Scaled Adjustment knob allows changes to the switching pressure to be made without a pressure gage. The PS is available in settings from 20 Pa to 4500 Pa. The compact size, adjustment knob and low cost make the PS the perfect choice for HVAC applications.

Product Applications:

Fan, Blower and filter monitoring
Pressure and Flow monitoring
Valve and damper monitoring

Service: Air & non aggressive gases
Material: ABS
Electrical Connection: 3 Screw terminal
Cable Entry: M16
Pressure Connection: Male 0 5 MM
Weight: 150 gms
Operation Temperature: -20 to 60° C
Storage Temperature: -40 to 85° C
Maximum Pressure: 50 kPA
IP Protection: IP54

2 Fixing Screws
2 Plastic duct connectors
2 m tube 0 4/7 mm
Metallic duct connectors

  • INTRODUCTIONS
  • TECHNICAL DATA
  • OPTIONAL ACCESSORIES
  • MODEL SUMMARY

Model Code

Pressure

range

Switching

difference

Accuracy of

Switching

point

Low limit typ.

Electrical

rating

resistive load

Accuracy of

Switching

Point

High limit typ.

Electrical

ratind

inductive load

PS1500

100...1500 pa

80 pa

100 Pa±1OPa

1500 Pa±150Pa

03A/250VAC

2A1250VAC
Aerosense Differential Pressure Switch Model PS 4500

 Aerosense Differential Pressure Switch Model PS 4500

Series PS Differential Pressure Switch With Dual Scale Field Adjustable Set Point Knob

The Series PS Differential Pressure Switch is Designed For Pressure, Vacuum and Differential Pressure. The Dual Scaled Adjustment knob allows changes to the switching pressure to be made without a pressure gage. The PS is available in settings from 20 Pa to 4500 Pa. The compact size, adjustment knob and low cost make the PS the perfect choice for HVAC applications.

Product Applications:

Fan, Blower and filter monitoring
Pressure and Flow monitoring
Valve and damper monitoring

Service: Air & non aggressive gases
Material: ABS
Electrical Connection: 3 Screw terminal
Cable Entry: M16
Pressure Connection: Male 0 5 MM
Weight: 150 gms
Operation Temperature: -20 to 60° C
Storage Temperature: -40 to 85° C
Maximum Pressure: 50 kPA
IP Protection: IP54

2 Fixing Screws
2 Plastic duct connectors
2 m tube 0 4/7 mm
Metallic duct connectors

  • INTRODUCTIONS
  • TECHNICAL DATA
  • OPTIONAL ACCESSORIES
  • MODEL SUMMARY

Model Code

Pressure

range

Switching

difference

Accuracy of

Switching

point

Low limit typ.

Electrical

rating

resistive load

Accuracy of

Switching

Point

High limit typ.

Electrical

ratind

inductive load

PS4500

500...4500 pa

180 pa

500 Pa±50 Pa

4500 Pa±200Pa

5A/250VAC

2A/250VAC
© 2016 Designtoonz & Company All rights reserved web counter
Enquire now